Tripp Lite SU5000RT4UTF. UPS topology: Double-conversion (Online), Output power capacity: 5 kVA, Output power: 4500 W. AC outlet types: NEMA 5–15R,NEMA 5–20R,NEMA L6-20R,NEMA L6-30R, Power plug: NEMA L6-30P, AC outlets quantity: 16 AC outlet(s). Typical backup time at full load: 3.5 min, Typical backup time at half load: 11 min. Form factor: Rackmount/Tower, Product color: Black, Rack capacity: 6U. Package width: 23.6" (599.4 mm), Package depth: 29.1" (739.1 mm), Package height: 22.2" (563.9 mm)
Manufacturer: Tripp Lite
SKU: 2686344
Manufacturer part number: SU5000RT4UTF
GTIN: 0037332157140
Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 6U rack/tower configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. 4U UPS power module with internal batteries and 2U step-down transformer installs in a total of 6 rack spaces (6U) with a maximum installed depth of only 20.75 in. / 52.7 cm. Maintains full-time sine wave output within 2% of 208 and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional SNMP/Web and contact-closure communications card accessories available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Included software packages include PowerAlert Local, PowerAlert Network Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of application types. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. L6-30P input, plus 2 L6-30R, 2 L6-20R and 12 5-15/20R outlets. External battery packs are field replaceable and hot swappable. $250,000 connected equipment insurance; - Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system in a 6U rack/tower configuration (4U UPS power module with internal batteries + 2U step-down transformer) - Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise - Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions - L6-30P input plug, plus 2 L6-30R, 2 L6-20R and 12 5-15/20R outlets - Included rail kits support rackmount installation of both included modules in 4 post racks - Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required for SU5000RT4UTF) - Optional 2-9USTAND supports upright tower placement (1 required for SU5000RT4UTF) - Maximum installed rack depth of only 20.75 in. / 52.7 cm - Maintains full-time sine wave output within 2% of 208V & 120V at 60Hz nominal in double conversion mode - Corrects brownouts to 156V at full load (100V at 50% load or less) - Corrects overvoltages to 290V at full load (300V at 90% load or less) - Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types - High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs - Network-grade AC surge and noise suppression - Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces - UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD) - Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces - Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification - Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) - HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices - Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations - LED/LCD display panel rotates for viewing in rackmount or tower configurations - Supports Emergency Power Off (EPO) via built-in interface - Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement - External battery packs are field replaceable and hot swappable - Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - $250,000 connected equipment insurance
Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 6U rack/tower configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. 4U UPS power module with internal batteries and 2U step-down transformer installs in a total of 6 rack spaces (6U) with a maximum installed depth of only 20.75 in. / 52.7 cm. Maintains full-time sine wave output within 2% of 208 and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional SNMP/Web and contact-closure communications card accessories available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Included software packages include PowerAlert Local, PowerAlert Network Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of application types. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. L6-30P input, plus 2 L6-30R, 2 L6-20R and 12 5-15/20R outlets. External battery packs are field replaceable and hot swappable. $250,000 connected equipment insurance; - Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system in a 6U rack/tower configuration (4U UPS power module with internal batteries + 2U step-down transformer) - Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise - Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions - L6-30P input plug, plus 2 L6-30R, 2 L6-20R and 12 5-15/20R outlets - Included rail kits support rackmount installation of both included modules in 4 post racks - Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required for SU5000RT4UTF) - Optional 2-9USTAND supports upright tower placement (1 required for SU5000RT4UTF) - Maximum installed rack depth of only 20.75 in. / 52.7 cm - Maintains full-time sine wave output within 2% of 208V & 120V at 60Hz nominal in double conversion mode - Corrects brownouts to 156V at full load (100V at 50% load or less) - Corrects overvoltages to 290V at full load (300V at 90% load or less) - Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types - High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs - Network-grade AC surge and noise suppression - Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces - UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD) - Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces - Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification - Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) - HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices - Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations - LED/LCD display panel rotates for viewing in rackmount or tower configurations - Supports Emergency Power Off (EPO) via built-in interface - Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement - External battery packs are field replaceable and hot swappable - Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - $250,000 connected equipment insurance
Products specifications
Attribute nameAttribute value
Package weight227.7 lbs
AC outlet typesNEMA 5–15R,NEMA 5–20R,NEMA L6-20R,NEMA L6-30R
CertificationUL1778 IEC 61000-4-5 1995 B
InterfaceUSB; DB9
Master (outer) case weight227.7 lbs