Tripp Lite SU16KRT uninterruptible power supply (UPS) Double-conversion (Online) 16 kVA 14400 W 10 AC outlet(s)

Tripp Lite SU16KRT. UPS topology: Double-conversion (Online), Output power capacity: 16 kVA, Output power: 14400 W. AC outlet types: C19 coupler, NEMA L6-30R, AC outlets quantity: 10 AC outlet(s). Typical backup time at full load: 5.5 min, Typical backup time at half load: 13.5 min. Form factor: Rackmount/Tower, Product color: Black, Housing material: Steel. Width: 17.5" (445 mm), Depth: 25.8" (656 mm), Height: 5.16" (131 mm)
Manufacturer: Tripp Lite
SKU: 2783443
Manufacturer part number: SU16KRT
GTIN: 0037332158222
Tripp Lite SU16KRT 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. - Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration - Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under - Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level - Hardwire input; 2 L6-30R and 8 C19 outlets - Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal - Supports 50/60Hz operation for worldwide frequency compatibility - Expandable runtime with optional external battery packs - Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - Battery independent restart
Tripp Lite SU16KRT 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. - Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration - Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under - Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level - Hardwire input; 2 L6-30R and 8 C19 outlets - Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal - Supports 50/60Hz operation for worldwide frequency compatibility - Expandable runtime with optional external battery packs - Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - Battery independent restart
Products specifications
Attribute nameAttribute value
Depth25.8"
Master (outer) case width40.3"
Country of OriginChina
Width17.5"
Height5.16"
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Power factor0.9
UPS topologyDouble-conversion (Online)
Cold startY
Crest factor3:1
Weight43 lbs
Master (outer) case weight601 lbs
Master (outer) case length51"
Master (outer) case height36"
Technical details
Product colorBlack
Packaging data
Package width40.3"
Package depth51"
Package height36"
Package weight601 lbs
Ports & interfaces
AC outlet typesC19 coupler, NEMA L6-30R
AC outlets quantity10 AC outlet(s)
USB 2.0 ports quantity1
Serial ports quantity1
Design
CertificationUL1778, CSA, FCC, IEC
Form factorRackmount/Tower
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Storage relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Power
Output power capacity16 kVA
Power protection featuresOver voltage, Under voltage
Features
Rack capacity12U
Cooling typeActive
LED indicatorsY
Noise level60 dB
Audible alarm(s)Y
Input operation voltage (min)100 V
Input operation voltage (max)300 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
Output power14400 W
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load5.5 min
Typical backup time at half load13.5 min
Hot-swap batteryY
Product tags
  • (56200)