Tripp Lite IS250HG surge protector White 2 AC outlet(s) 120 V 72" (1.83 m)

Tripp Lite IS250HG. Surge energy rating: 940 J, AC outlets quantity: 2 AC outlet(s), AC outlet types: NEMA 5–15R. Power plug: NEMA 5–15P. Product color: White, EMI/RFI noise filtering: 65 dB, Country of origin: Taiwan. Cable length: 72" (1.83 m), Weight: 13.2 lbs (5.99 kg), Width: 4.75" (120.6 mm). Certification: TAA, UL60601-1
Manufacturer: Tripp Lite
SKU: 2511286
Manufacturer part number: IS250HG
GTIN: 0037332116208
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250HG includes 2 NEMA5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit housing; ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 2 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle) - The IS250HG Medical Grade Isolation Transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression. - Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line - Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles; ideal for the protection of sensitive electronic equipment in - patient-care areas. - Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps - Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment - Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades - Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops - Additional surge suppression components placed at the line input and output combined with full line isolation provide continuous filtering of a full range of - power line noise in all modes - Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the worst of power - environments to harmless levels - Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode - Includes 2 widely spaced NEMA 5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection - and lighted power switch. - Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250HG includes 2 NEMA5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit housing; ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 2 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle) - The IS250HG Medical Grade Isolation Transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression. - Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line - Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles; ideal for the protection of sensitive electronic equipment in - patient-care areas. - Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps - Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment - Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades - Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops - Additional surge suppression components placed at the line input and output combined with full line isolation provide continuous filtering of a full range of - power line noise in all modes - Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the worst of power - environments to harmless levels - Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode - Includes 2 widely spaced NEMA 5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection - and lighted power switch. - Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Products specifications
Attribute nameAttribute value
Capacity250 W
Master (outer) case GTIN (EAN/UPC)10037332116205
Master (outer) case weight58.6 lbs
Master (outer) case height15.2"
EMI/RFI noise filtering65 dB
Nominal current output2.1 A
Country of OriginTaiwan
Width4.75"
Depth7.75"
Height4.5"
Weight13.2 lbs
Cable Length72"
Master (outer) case length14.5"
Master (outer) case width10.8"
Technical details
Product colorWhite
Sustainability certificatesRoHS
Packaging data
Package width6.9"
Package depth10.3"
Package height7"
Package weight14.5 lbs
Ports & interfaces
AC outlets quantity2 AC outlet(s)
AC outlet typesNEMA 5–15R
Power plugNEMA 5–15P
Design
CertificationTAA, UL60601-1
Power
Nominal input voltage120 V
AC input frequency60 Hz
Weight & dimensions
Dimensions (WxDxH)4.75 x 7.75 x 4.5"
Features
Surge energy rating940 J
On/off switchY
Logistics data
Quantity per master (outer) case4 pc(s)
Product tags
  • (56199)